Mold in Construction
-
Mold in Construction
The following are links to all of the items in this collection:
Summary Statement
An in-depth presentation on the nature of mold, the cost of mold and ways to prevent it during construction. Part of a collection. Click on the 'collection' button to access the other items.
February, 2003
Presented at the Construction Safety Council's 13th Annual Construction Safety & Health Conference & Exposition, Rosemont, Illinois, February 2003. |
DISCLAIMER
- St. Paul makes
no warranty of any kind, and is not liable for any damages that may
arise from use of this information.
- We ARE NOT LAWYERS,
and can't give legal advice. If you need it, talk with your own lawyer.
- Our discussion
of a topic does not change or create insurance coverage- your insurance
policy does that.
- This class does
not, and cannot cover all conditions you may encounter in the real world.
- YOU always have FINAL responsibility for YOUR safety.
- New York City
- 150 families
file suit against housing complex owner claiming failure to eliminate
mold.
5 are wrongful death suits.
- 150 families
file suit against housing complex owner claiming failure to eliminate
mold.
- Florida
- Construction defect claim against architect, CM and subs. $11.5 million awarded
- California
- $33,000 settlement regarding roof leaks
- Texas
- $30 million
bad faith claim against insurer over mold
- Reduced to $4 million
- $30 million
bad faith claim against insurer over mold
- Ed McMahon
- $20 million
against insurer and contractor
- Settled for $250,000
- $20 million
against insurer and contractor
- Coverage is major issue at this time
- All insurers
are trying to get exclusions
- $1.2 billion paid out in 2001
- $2.5 billion paid out in 2002
Session Overview
- Health and mold
- Reasons for mold growth
- Prevention
- Assessment guidelines
- Remediation procedures
- Mold is everywhere
- Only 3 things needed for mold growth
- Mold will always be here
- Can't eliminate the first two - the only option is #3 - control moisture
- Fungus is one of the kingdoms (plants, animals)
- Mold is a term of convenience
- All mold is fungus, not all fungus is mold.
- We will use the terms interchangeably
Health and Mold
- Potential mold
reactions depend on:
- Species involved (there are 1000s of them)
- Metabolic products of species
- Duration and intensity of exposure
- Susceptibility
of individual
- Just because mold is present does not create a hazard - it is always there.
- Allergic reactions - probably the most common response
- Infections - rare (e.g. histoplasmosis). 95% recover naturally. Medical facilities are high risk location.
- Irritation - from chemicals produced by mold.
- Mycotoxins -
chemicals produced by some (not all) molds
.- Some extremely toxic - some therapeutic
- Most have little or no research on health effects
- Most human
disease due to eating contaminated food or huge agricultural exposures
- NOT inhalation
- Toxic Mold -
Stachybotrys
- 1994 - 10 acute pulmonary hemosiderosis in infants in Cleveland - Stachybotrys found in houses
- 2000 - CDC study - not enough evidence to conclude an association between indoor mold and children's' condition
- CDC position
on health effects - no consensus
- Texas Medical Association - Council of Scientific Affairs
"Levels of exposure in the indoor environment, dose-response data in animals, and dose-rate considerations suggest that delivery by the inhalation route of a toxic dose of mycotoxins in the indoor environment is highly unlikely at best......."
American College of Occupational and Environmental Medicine October 2002
- Annals of Allergy
Asthma Immunology Vol. 87 Dec. 2001 p.57-63
Stachybotrys: Relevance to Human Disease
Conclusions: The current public concern for adverse health effects from inhalation of stachybotrys spores in water-damaged buildings is not supported by published reports in the medical literature
- Annals of Allergy
Asthma Immunology
Vol. 87 Dec. 2001 p. 52-6
Fungi: Toxic Killers or Unavoidable Nuisances
Conclusions: The review led to the conclusion that the primary effect from fungal exposure is allergic disease, and that the evidence for inhalation disease resulting from mycotoxin exposure in residential and office settings is extremely weak.
- Few medical tests available
- Can only document that exposure has occurred
- Can not determine source, place, time of exposure
- Mold exposure
occurs naturally all the time
- both indoor and outdoor
- Primary reason
- moisture accumulation
- Design flaw
- Construction flaw (e.g. leaky roof, vapor barrier, installation of wet materials)
- Pipe leak,
water overflow
- Growth can start within 48 hrs.
- Modern buildings seem particularly susceptible - tight construction
- Increase of wall board vs. metal mesh and plaster
- Prevent moisture accumulation
- US EPA study - 45% of office buildings surveyed had active water leaks
- Consult envelope engineer on geometrically complex buildings for water tightness
- Document any recommended changes to Architect of Record.
- If recommendation is rejected copy to owner and your file.
- Don't just "shrug and build it"
- Renovations or additions - preexisting mold survey.
- Prequalify potential subs that they have expertise in specific application
- Consult manufactures
of moisture critical products:
- Fitness for intended service
- Confirm product's proper application
- Provide preferred
installers
- Proper sequencing of work - keep interior materials away from exterior conditions
- Inspect materials
at delivery
- Preexisting mold
- Proper moisture
content per manufacturer
- Storage
- Dry location
- Off the ground
- Loose tarps or sheets to allow air flow
Be sure foundation is dry
- Drain away
- Slope away
- Roof drains properly supported and braced
- Sprinklers
will not water the foundation
- Proper insulation on chilled water pipes
- Double check
points where moisture may enter
- Doors
- Windows
- Flashings and caulking
- Waterproof membranes (proper lapping at joints and corners
- Roofing systems and penetrations
- Balconies
and decks
- Prearrange drying
equipment
- Fans
- Dehumidifiers
- Wet-dry vacs
- Dry materials as quickly as possible
- If possible, ventilate wall cavity
- Be sure it is
safe to use equipment
- Electrical
- Ventilation
Hidden moisture during 1993 Mississippi floods.
- Pipe chases/utility tunnels
- Above drop ceilings
- Under carpeting
- Wall cavities
- HVAC system
- No internal lining - bare galvanized sheet metal
- Cooling coil drip pans
- Filters - good quality and in place
- Humidity
levels - 30-50% RH
Prevention - Drywall
- Greenboard -
moisture resistant
- Wax added to gypsum and paper cover
- More resistant to moisture uptake
- Cost increase
to use greenboard throughout 1 study - 0.08 - 0.6% increase
- Capillary breaks or moisture barriers between gypsum and masonry materials
- Double check
all water lines
- Proper installation
- Connections leak tight
- Proper insulation
- Multiple
checkers for leak detection
- HVAC commissioning - actual air flow tests critical
- Consider interim
inspections for mold issues
- Architect
- Envelope engineer
- Mechanical engineer
- Materials
manufacturer's representative
- New building
owners must be trained on:
- HVAC system
- Maintenance of structure
- Water damage
- Vent moisture appliances
- Humidity control
- Sprinkler
systems not watering building
- DO NOT use outdoor
fungicides for indoor situations.
- Three steps to
quality assurance
- Build in strict accordance with plans and specifications
- Design professionals correct flaws in plans and specs that are likely to allow intrusion
- Document every step, including photos of key installations.
Prevention
"If builders and insurance companies aren't sensitive (to mold concerns) then they are provoking people to bring claims to justify their own fears" Plaintiffs often win cases with the argument that mold growth was exacerbated by the insurance company's or builder's action, but not proof that the mold made them sick.
John Sweeney Miles & Stockbridge Law Firm
Assessment
- No generally accepted levels for mold in environment.
- 1986 ACGIH proposes
mold TLV
- 500 CFU/M3
in office environment. Indoor/outdoor ratio should be less than
0.33.
- 500 CFU/M3
in office environment. Indoor/outdoor ratio should be less than
0.33.
- Guidelines deleted in 1987. Lack of scientific data to support levels and difficulty in interpretation.
- Visual inspection is the most important initial step in identifying a possible contamination problem.
- Testing not required for remediation.
- Lots of variables in air monitoring collection and interpretation of results.
- "Bulk or surface
sampling is not required to undertake a remediation." "Air sampling
for fungi should not be part of a routine assessment...."
NYC Guidelines - "If it is not possible to sample properly, it would be preferable to not sample. Inadequate sample plans may generate misleading, confusing and useless results. US EPA
- Moisture meters
- Mold growth may occur up to 1 meter past high water mark or visual mold
- In addition look
for:
- Earthy, musty odor
- Discolored plaster, wall board, building materials
- Suspected water accumulation or intrusion
Assessment - Air Monitoring
- Simultaneous
samples collected in
- Problem area
- Outdoors
- Compare results
- Look for higher levels indoors, or different molds - suggests amplification source
- Can not prove sources of health complaints
- Can not suggest remediation procedures
- Remember - mold is everywhere.
- Having said all
that: Situations that require it:
- Litigation
- Building management requires evidence that identified source is being spread
- Building management (occupants) insist
- "Sampling should be done only after developing a sampling plan that includes a confirmable theory regarding suspect mold sources and routes of exposure." US EPA
- What will we learn?
- How and who collects and analyzes samples?
- What criteria to interpret the data?
Remediation
- To conquer mold conquer moisture problems.
- Most important action STOP THE MOISTURE.
- Don't bother doing anything until the moisture source is eliminated
- Non-porous materials (e.g. glass, brick, plastic)
- Porous materials (e.g. carpet, drywall, cloth)
- EPA and OSHA do not recommend routine use of bleach or other biocide
- Read labels
- Follow directions
- Use PPE
- Don't be Mr. or Ms. Science and start mixing things.
- In some situations
- decontaminate and encapsulate
- Limited mold growth
- Can access both sides of drywall
- Zinc rich
paints can be used to control mold
- ShieldZ - Zinzer
- Foster 40/20 - H.B. Fuller
- Ozone generators - not recommended
- UV lights - not recommended
- Level 1 - Small areas - 10 ft2 (ceiling tile)
- Level 2 - Medium - 10-100 ft2 (one to several wallboard panels)
- Level 3 - Large - over 100 ft2
- New York City has additional guidance for HVAC remediation
- EPA Guidelines assume clean water damage
- Get help for sewage, chemical/biological contaminated water damage
- Everything is just a starting point - each job needs professional judgment
- Level 1 - Trained building staff
- Level 2-3 - "Qualified"
safety professional makes cases-by-case determination
(From NYC Guidelines)
- Level 1 - N95 disposables or better
- Level 2 - Full face with N100 filters
- Level 3 - PAPR with N100 filters
- Remember OSHA Respirator Program
- All levels
- Impervious gloves - mid-forearm
- Goggles - sealed or indirect vent only
- Disposable coveralls
- Hand and face washing station
- Level 1 - none required
- Level 2 - increasing levels as specified
- Level 3 - under negative pressure similar to asbestos abatement
- All levels - light water misting - not soaking
- Lots of professional judgment is needed here
- Bag
- Rinse
- Toss - check with local authorities just to be sure. Moldy material is NOT RCRA hazardous waste.
- OSHA Draft Mold Recommendations - release date unknown. VERY similar to US EPA
- AGC of America
- Managing the Risk of Mold in the Construction of Buildings - March
2003
- States planning
or taking legislative action
- Connecticut
- Massachusetts
- New York
- Virginia
- California
- Maryland
- Texas
- Mold will always be with us.
- Health effects may be scientifically questionable, but public perception is reality.
- To control mold, control moisture.
- Visual inspection is first step in assessment
- No PEL or TLV for mold.
- EPA and NYC have remediation guidelines
This program is only a tool to assist you in managing your legal responsibility to maintain safe premises, practices, operations and equipment, and is not for the benefit of any other party. The program does not cover all possible hazardous conditions or unsafe acts that may exist, and contains no legal advice. For decisions regarding use of the practices suggested by this program, follow the advice of your own legal counsel. St. Paul disclaims all warranties whether implied, express or statutory, including without limitation, implied warranties of merchantability, fitness for use and fitness for a particular purpose. Implementation of any practices suggested by this program is at your sole discretion, and St. Paul will have no liability to any party for any damages including, but not limited to, direct, indirect, special or consequential damages, arising out of or in connection with the information provided or its use.
Further, this document does not amend, or otherwise affect, the terms, conditions or coverages of any insurance policy issued by The St. Paul. No part of this document or any of our risk control activities associated with or leading up to the creation of this document, is a representation that coverage does or does not exist for any particular claim or type of claim under any such policy. Whether coverage exists or does not exist for any particular claim under any such policy depends on the facts and circumstances involved in the claim and all applicable policy wording.
Mold in Construction Checklist